MAINTENANCE-FREE, VALVE-REGULATED,
SEALED LEAD ACID BATTERIES.
DESIGNED FOR DEEP CYCLE 50% DISCHARGE RUGGED USE.
SOLAR ENERGY or PHOTOVOLTAIC APPLICATIONS - HYDROELECTRIC APPLICATIONS - WIND ENERGY APPLICATIONS

All PRICES INCLUDE SHIPPING/DELIVERY TO CONTINENTAL U.S.

Standard Terminals: All batteries with a "T" in the part number now incorporate copper alloy M8 terminals except the PVX-340T & PVX-420T which are M6. All batteries supplied with silicon bronze bolts, nuts, and washers as required for installation. Torque Value M6: 35 in-lbs / 4.0 nm. Torque Value M8: 70 in-lbs / 7.9 nm.
Optional Terminals: L Blade or Automotive post type terminals are available installed by adding the appropriate suffix: "L" for L Blade or "A" for automotive post. Handles: All part numbers include lifting handles except the PVX-490T, PVX-560T, and PVX-2240T. Ratings: Capacity ratings are stated at 77F (25 C) to 1.75 volts per cell. Drawings: Click on the part number in the table above or contact the factory.
Solar Batteries have No exposed lead terminals. This change was made to improve environmental safety and health. Sun Xtender reacted positively to the predominant indoor residential, commercial, and industrial solar installation of their products.
Solar Batteries are UL listed. Approved by Building Inspectors. This coveted mark, and subsequent testing of these solar batteries was done by the manufacturer to ease customer`s ability to install their products. Now UL approved paperwork is available from both the manufacturer, and this website. UL Battery Documentation - UL Listed Batteries BR>
SUN-XTENDER® BATTERY DESIGN FEATURES
Copper Alloy Terminals for improved electrical connections.
No exposed lead terminals. This change was incorporated to improve environmental safety and health.
Threaded insert terminals are recessed to prevent short circuits across battery connections.1
New cover is flat top design. No protruding or exposed vent valves.1
Built in lifting handles, except PVX-490T, PVX-560T, and PVX-2240T.
Reinforced container walls to reduce bulging.
High Impact Strength Copolymer Polypropylene Case and Cover.
Completely Sealed Valve Regulated Construction.
Immobilized Electrolyte Non-Spillable.
Maintenance Free Design Never Requires Watering.
Absorbed Glass Mat (AGM) Micro-porous Glass Separators retain electrolyte.
Flame Arresting Pressure Regulated Safety Valves.
UL Recognized Systems Component.
Positive Plates - Proprietary Lead Calcium Alloy- Negatives Plates - Lead Calcium.
Low Self Discharge Rate Approximately 1 % per month at 25 C (77 F).
Operate over a Wide Range of Temperatures from -40 C (-40 F) to +72 C (+160 F).
Classified as "Non-Spillable Battery" for transport. Complies with DOT HMR49, Non-Hazardous Materials.
1 Threaded Insert "T" type Features.
SOLAR BATTERY CHARGING INSTRUCTIONS
Initial charge or recharge: 2.37 to 2.40 volts per cell at 25 C (77 F).
Float charge: 2.20 to 2.22 volts per cell at 25 C (77 F).
Equalize charge: 2.40 volts per cell at 25 C (77 F)*.
Temperature compensation = ±3.75 mV. per cell per degree C [Reference to 25 C (77 F)].
This is for battery temperature (not ambient temperature) and is useful for battery temperatures from 0° C (32° F) to 40° C (104° F).
Contact Concorde Battery Corporation for battery temperatures that exceed this range. *AGM Batteries are sealed by the manufacturer. These solar batteries are UL approved because of this seal. However, this design prevents the addition of water to your solar battery. An equalize charge is a deliberate boiling of the electrolyte under an overcharge condition to "FORCE" power back into the system. Although this may recover elder solar batteries, it may also run them out of electrolyte, rendering your bank of solar batteries useless. The manufacturer reccommends you equalize your batteries only 2 times over their lifespan.
Specifications subject to change without notice.
AGM Batteries Available
All Available AGM Batteries
Battery Comparison Table - AH & Capacity
Battery Comparison Table - Size Weight

Lifeline Deep Cycle AGM Battery Specifications
Lifeline Deep Cycle AGM Batteries by Size
Lifeline OEM - RV & Marine List
Lifeline AGM Battery Features
Lifeline AGM Battery SOC, OCV, and DOD Info
Lifeline AGM Battery Performance Graphs
Lifeline AGM Battery Charging Procedures
Lifeline AGM Batteries History
Lifeline AGM Batteries FAQ
Lifeline AGM Battery Safety
Battery, Inverter, and Generator Failover Calculator
AC - DC Lifeline AGM Battery Bank Sizing Calculator
DC - DC Lifeline AGM Battery Bank Sizing Calculator
DC Reserve Minutes Calculator
AGM Battery Users Manual Part 1 (1 of 2)
AGM Battery Users Manual Part 2 (2 of 2)

Sun Xtender Deep Cycle AGM Battery Specifications
Sun Xtender Deep Cycle AGM Batteries by Size
Sun Xtender AGM Battery Features
3rd Party Sun Xtender AGM Battery Test Results
SunXtender AGM Battery Charging Procedures
Sun Xtender AGM Batteries History
Sun Xtender Battery Service Instructions
Sun Xtender Technical Documentation
AC - DC Sun Xtender AGM Battery Bank Sizing Calculator
DC - DC Sun Xtender AGM Battery Bank Sizing Calculator

Optima Battery Features
Optima Red Top Battery Specifications
Optima Red Top Batteries by Size
Optima Blue Top Battery Specifications
Optima Blue Top Batteries by Size
Optima Yellow Top Battery Specifications
Optima Yellow Top Batteries by Size
|

Chairman Traction / Standby / Wheelchair Batteries
Battery Chemistry Comparison - VRLA vs GEL vs AGM
Comparison Between Gel Batteries and AGM Batteries

Total Power Racing Battery Features
Total Power AGM Racing Battery Specifications
Total Power Racing Lightweight Batteries by Size
Battery Chemistry Comparison - VRLA vs GEL vs AGM
Comparison Between Gel Batteries and AGM Batteries

Rock Racing Battery Features
Rock AGM Racing Battery Specifications
Total Power Racing Lightweight Batteries by Size
Battery Chemistry Comparison - VRLA vs GEL vs AGM
Comparison Between Gel Batteries and AGM Batteries
Shipping, Safety, and Legal
Lifeline, SunXtender, Total Power, and Rock Racing Battery Material Safety Data Sheet - MSDS (pdf)
Lifeline, SunXtender, Total Power, and Rock Racing Battery Safety Bulletin
Lifeline, SunXtender, Total Power, and Rock Racing Battery Transportation Information DOT
AGM Battery Applications and Benefits
AGM Battery Efficiency and Peukert Coefficients
Custom Uninterruptable Power Supply - Custom UPS
Uninterruptable Power Supply Kits - UPS Kits
Solar Powered Off Grid Housing
AGM Battery Installation Considerations
Hydrogen Venting Systems
|
|
|
|